Special purpose signal conditioners
Stroud Instruments special purpose units comprise a diverse range of signal converters :-
- Set-point generators
- Raise-lower unit / Ramp generator
- High or Low analogue signal selectors
- Analogue signal comparator
- Status signal long distance transmitter / receiver
- Analogue signal long distance transmitter / receiver
- Rate limiters
- Rate of change monitor
- Status to analogue converter
- BCD to analogue converter
- Analogue to BCD conversion
Quick links
Set-point generators
See the set-point generator selection guide...
Analogue set-point
This range of units provide a current (mA), voltage or pulse output, the magnitude of which is controlled either by a front panel control, a remotely mounted potentiometer or may be a fixed set-point.
B12-1 Series set-point generators
These units provide a current, voltage or pulse output, the magnitude of which is controlled by:
- B12-1A -a front of module mounted multi-turn dial (illustrated).
- B12-1RP -a remote set-point with the set-point potentiometer and dial supplied loose for remote mounting e.g. in a control panel or enclosure door or
- B12-1F -a fixed output which is internally set to the level required.
Wall or DIN rail mounting.
107-1 Series set-point generators
Available for spares, additions and replacements for existing applications.
- 107-1A -a front of module mounted dial (illustrated).
- 107-1RP -a remote set-point supplied loose for remote mounting
- 107-1F -a fixed output type.
For the description see the latest versions - the B12-1 Series set-point generators above.

112-52 Signal generator
Provides a pulsed output signal for testing, simulation and other applications requiring a variable set-point frequency. The set-point control is either a front panel mounted multi-turn dial or a set-point potentiometer and multi-turn dial supplied loose for remote mounting.
Wall or DIN rail mounting.
112-65s Raise - Lower (set-point)
A versatile programmable instrument which, configured as a Raise Lower Unit (set-point generator), provides a scaleable ramped output signal. Control of the output signal is provided by three inputs; Raise, Lower and Reset. Optional PC software provides user selection of all functions except output signal rise and fall times which are user selectable by internal switches. See datasheet for full details. Wall or DIN rail mounting.
Ramp generator
112-65s Ramp generator
Configured as a Ramp Generator this unit provides a scaleable ramped output signal controlled by three inputs; Start, Stop and Reset. The ramp signal may be set to:
- Low to High
- High to Low
- Low to High to Low
- High to Low to High
High / low signal selectors
112-20A Low selector, 112-21A High selector
These instruments will provide an output which is equal to, or proportional to, the highest (112-21A) or the lowest (112-20A) of up to six input signals. The output can be converted into a signal of a different type.
Wall or DIN rail mounting.
Analogue comparator
112-22A Comparator
Compares two input signals and provides a relay output which changes state when the signals differ by an amount set by a front panel control. Two relays each provide one change-over and one normally open contact. One relay operates when input A is greater than input B, the other when input B is greater than input A. Wall or DIN rail mounting.
Status signal long distance transmission
COM-60 Status transmitter, COM-61 Status receiver
Provides a solution for long-distance transmission of a switched state, e.g. a high / low alarm, over telecom lines where a copper connection is unavailable. The Transmitter accepts either open-collector, volt-free contact or voltage change type inputs and converts off/on states into 400Hz/2000Hz tones for transmission.
The Receiver converts the transmitted tones into a relay output (SPCO).
Wall or DIN rail mounting.

Analogue signal long distance transmission
COM-70 Analogue transmitter, COM-71 Analogue receiver
Provides a solution for long-distance transmission of an analogue signal (4-20mA or 1-5V) over telecom lines where a copper connection is unavailable. The Transmitter converts the analogue input into 400-2000Hz sinewave signal. The Receiver converts the transmitted tones into a 4-20mA signal. Wall or DIN rail mounting.

Rate limiters
B12-17 Series rate limiters
Provide a range of isignal conditioners for controlling the rate of change (e.g. signal damping) of a process signal. These units may also provide signal conversion. The time constant is adjustable by a front panel mounted dial.
Wall or DIN rail mounting.
107-17 Series rate limiters
Available for spares, additions and replacements for existing applications.
For the description see the latest versions - the B12 Series rate limiters above.

Rate of change monitor
B12-18 Signal conditioner (rate of change monitor)
Provides an output signal, with a magnitude proportional to the rate of change of the input signal. The output signal can be configured to indicate decreases as well as increases in the rate of change of the process variable.
Wall or DIN rail mounting.
107-18 Signal conditioner (rate of change monitor)
Available for spares, additions and replacements for existing applications.
For the description see the latest version - the B12 Series Rate of Change Monitor above.

Status to analogue converter
112-61s Status to analogue converter
Provides an analogue output which is proportional to the number of active inputs. Each unit will accept up to five inputs but multiple units (current output) may be connected in parallel. The number of input signals required for full scale output is set by internal switches. Wall or DIN rail mounting.
BCD to analogue converters
116-24A BCD to analogue converter
Accepts up to four decades of BCD data and converts to a proportional analogue signal. This unit is programmable for input range for FSD and output signal range and type. The input range for full scale may be set anywhere between 0 - 9999. The output signal may be set to either 0-10mA, 0-20mA, 2-10mA, 4-20mA, 0-1V, 0-5V, 0-10V, 0.2-1.0V, 1-5V or 2-10V. Also provides a trickle-charging output for battery-powered optical encoders.
Wall mounting.