Process adjusters, ramp generator, raise lower...

Designed to provide fixed or adjustable set-point signals, this range of instruments includes fixed analogue output types, manually adjustable analogue or pulse / frequency output types and time-based manual/process signal controlled analogue output types.

Time-based manual or process signal controlled
The 112-65s Raise-Lower / Ramp Generator provides a time-based output, controlled by remote manual or process signals, which ramps up/down to programmable set-points. 

 

Set-point generator selection guide

PLEASE NOTE other outputs can be provided.
For 107 types:

Currents from 0-1mA to 0-30mA;
Voltage from 0-1V to 0-10V;
Bidirectional voltage signals (e.g. ± 5 V); Reverse acting current and
voltage signals (e.g. 4-20mA to 20-4mA); Current sink output signals.
For the 112-65s:
Currents from 0-1mA to 0-30mA; Voltage from 0-1V to 0-14V;
Current sink output signals.
For the 112-52 and 160-52:
Other pulse output voltages e.g. 5V, TTL, etc.
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Key: This symbol, where it appears in the table below, links to a Set-point Generator data sheet Datasheet; This symbol, where it appears in the table below, links to a Set-point Generator user guide User guide

TYPE

SET-POINT CONTROL

OUTPUT

MAIN FEATURES

FIELD
RE-RANGE

POWER

MOUNTING

107-1A
download Set-point Generator information sheet
Front panel mounted ten-turn dial Current
0-10mA
0-20mA
4-20mA
Current sink
Voltage
0-5 V
1-5V
etc.  
Continuously variable output No AC 110,200,220,240
~
12, 24, 48VDC
Wall or DIN rail
107-1F
download fixed value Set-point Generator information sheet
Fixed set-point (no adjustment) Fixed output No AC 110,200,220,240
~
12, 24, 48VDC
Wall or DIN rail
107-1/RP
download Set-point Generator with remote control information sheet
Via remote set-point potentiometer Continuously variable output No AC 110,200,220,240
~
12, 24, 48VDC
Wall or DIN rail
Raise- Lower / Set-point
112-65s
download Raise - Lower (Set-point) information sheet Download Raise - Lower (set-point) user guide
spacer for signal converter comparison table
Voltage, current, open-collector or volt-free contacts
spacer for signal converter comparison table
Current
0-10mA
0-20mA
4-20mA
Current sink
Voltage
0-5 V
1-5V
0-10 V
etc.
spacer for signal converter comparison table
Raise and Lower input signals control ramping up and down of output signal. e.g whilst Raise signal is present, output rises. Output min / max values (set-points), action taken with simultaneous raise /lower signals, etc. all programmable.
spacer for signal converter comparison table
Yes
via PC software
spacer for isolator comparison table
Universal 85-265 VAC
~
12, 24, 48VDC
spacer for signal converter comparison table
Wall or DIN rail
spacer for signal converter comparison table
Pulse Generator
112-52
download Pulse Generator with remote control information sheet
Front panel mounted ten-turn dial Optically isolated open collector transistor
~
24V pulse
~
Relay C/O contact
etc.
Continuously variable output
~
Remote control option
No AC 110,200,220,240
~
12, 24, 48VDC
Wall or DIN rail
Pulse Generator
160-52
download Pulse Generator with remote control information sheet
Front panel mounted switch Optically isolated open collector transistor
~
24V pulse
~
Relay C/O contact
etc.
Switched output pulse rates
~
Remote output inhibit function
No AC 110,200,220,240
~
12, 24, 48VDC
Wall
~
DIN rail
~
Rack mount
~