Home
» Products »
Signal converters
A versatile range of signal
converters providing signal level and signal type conversion, booster,
inverter, amplifier, conditioner and scaling functions for process control
instrumentation. SIL signal converters units will convert voltage or current
signals, or inputs from resistance transducers e.g. variable resistances,
potentiometers, resistance thermometers, into standard voltage or current
process signals. The 107-1/B Bridge Amplifier caters for millivolt input
signals including those from bridge type transducers (e.g. strain gauge, load
cells and pressure transducers).
Typical applications for signal converters
- Solving current loop loading problems
- Converting voltage signals to current, current signals to
voltage or converting resistance type signals to current or voltage.
- Scaling of process variables
- Interfacing field sensors, transducers and transmitters
with indicators, PLCs, and other process control instrumentation.
- Boosting signals to drive long signal lines
- Signal level changing
|
|
| |
Signal Converters selection guide
PLEASE NOTE other outputs and, with the
exception of the Bridge Amplifier, inputs within the following ranges can
be provided.
INPUTS: Current from 0-1mA to 0-30mA,
Voltage from 0-1V to 0-250V, Bidirectional voltage signals (e.g. ± 5
V) (NB other mV input ranges for the Bridge Amplifier can be
provided) OUTPUTS: Currents from 0-1mA to 0-30mA, Voltage from 0-1V to
0-10V Bidirectional voltage signals (e.g. ± 5 V) or reverse acting
current and voltage signals (e.g. 4-20mA to 20-4mA) are possible. Current sink output is available on most
types. - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Key:
Datasheet;
User guide
|
TYPE |
INPUT |
OUTPUT |
MAIN FEATURES |
FIELD RE-RANGE |
POWER |
MOUNTING |
107-1 Signal Converter
 |
Current 0-10mA 0-20mA 4-20mA Voltage 0-5 V 1-5 V Resistance Min change 50R max 10k PRT PT100 or PT130 Min span 40 deg C Max span 500
deg C |
Current 0-10mA 0-20mA 4-20mA Current sink Voltage 0-5 V 1-5V etc |
High impedance drive current
output option ~ Current input loop integrity* ~ accepts either
current, voltage, 2/3 wire resistance or RTD inputs |
No |
AC 110,200,220,240 ~ 12, 24, 48VDC |
Wall or DIN rail |
107-1/i Signal Inverter
 |
As above |
As above |
Provides signal
inversion ~ other signal conditioning features as above |
No |
AC 110,200,220,240 ~ 12, 24, 48VDC |
Wall or DIN rail |
107-1/B Bridge Amplifier
  |
Milli-volt adjustable ranges from 0-10mV to
0-100mV Bridge Transducers Strain
gauge Load cells etc. |
Current 0-10mA 0-20mA 4-20mA Current sink Voltage 0-5 V 1-5V etc |
Isolated and stabilised power
supply for excitation of bridge type circuits and other transducers requiring a
constant voltage. ~ User adjustable ranges ~
 |
Yes - input ranges |
AC 110,200,220,240 ~ 12, 24, 48VDC |
Wall or DIN rail |
*Current input loop maintained when
module unplugged
For more in our range of signal