process measurement control display instrumentation products image
sil flash

Home » Products »

Signal converters

A versatile range of signal converters providing signal level and signal type conversion, booster, inverter, amplifier, conditioner and scaling functions for process control instrumentation. SIL signal converters units will convert voltage or current signals, or inputs from resistance transducers e.g. variable resistances, potentiometers, resistance thermometers, into standard voltage or current process signals. The 107-1/B Bridge Amplifier caters for millivolt input signals including those from bridge type transducers (e.g. strain gauge, load cells and pressure transducers).

 

Typical applications for signal converters

  • Solving current loop loading problems
  • Converting voltage signals to current, current signals to voltage or converting resistance type signals to current or voltage.
  • Scaling of process variables
  • Interfacing field sensors, transducers and transmitters with indicators, PLCs, and other process control instrumentation.
  • Boosting signals to drive long signal lines
  • Signal level changing

For more in our range of signal converters and signal conditioners - see
Signal Conditioners index

 
 

Signal Converters selection guide

PLEASE NOTE other outputs and, with the exception of the Bridge Amplifier, inputs
within the following ranges can be provided.

INPUTS: Current from 0-1mA to 0-30mA, Voltage from 0-1V to 0-250V,
Bidirectional voltage signals (e.g. ± 5 V)
(NB other mV input ranges for the Bridge Amplifier can be provided)
OUTPUTS: Currents from 0-1mA to 0-30mA, Voltage from 0-1V to 0-10V
Bidirectional voltage signals (e.g. ± 5 V) or reverse acting current and
voltage signals (e.g. 4-20mA to 20-4mA) are possible.
Current sink output is available on most types.
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Key: . Datasheet; . User guide

TYPE

INPUT

OUTPUT

MAIN FEATURES

FIELD
RE-RANGE

POWER

MOUNTING

107-1
Signal Converter
download Signal Convertor information sheet Download Signal converter user guide
Current
0-10mA
0-20mA
4-20mA
Voltage
0-5 V
1-5 V
Resistance
Min change 50R
max 10k
PRT
PT100 or PT130
Min span 40 deg C
Max span 500 deg C
Current
0-10mA
0-20mA
4-20mA
Current sink
Voltage
0-5 V
1-5V
etc
High impedance drive current output option
~
Current input loop integrity*
~
accepts either current, voltage, 2/3 wire resistance or RTD inputs
No AC 110,200,220,240
~
12, 24, 48VDC
Wall or DIN rail
107-1/i
Signal Inverter
download Signal Converter information sheet Download Signal converter user guide
As above As above Provides signal inversion
~
other signal conditioning features as above
No AC 110,200,220,240
~
12, 24, 48VDC
Wall or DIN rail
107-1/B
Bridge Amplifier
Download Bridge amplifier information sheet Download Bridge amplifier user guide.
Milli-volt
adjustable ranges
from
0-10mV to 0-100mV
Bridge
Transducers

Strain gauge
Load cells
etc..
Current
0-10mA
0-20mA
4-20mA
Current sink
Voltage
0-5 V
1-5V
etc.
Isolated and stabilised power supply for excitation of bridge type circuits and other transducers requiring a constant voltage.
~
User adjustable ranges
~
.
Yes -
input ranges.
AC 110,200,220,240
~
12, 24, 48VDC.
Wall or DIN rail.

*Current input loop maintained when module unplugged

For more in our range of signal converters and signal conditioners - see the Signal Converters index