Tracker T300 Signal
Conditioners Data Aquisition PID Control |
Low cost Signal Conditioner, Trip
Amplifier and PID Controller, for use in a variety of process applications. Its
small size enables high packing density on standard TS35 DIN rail. A built in
power supply, transmitter excitation and serial RS485 interface provides
genuine single loop integrity with distributed data acquisition and
control |
22.5 mm wide 99 mm high 112.6
mm deep |
| |
Signal conditioning /data aquisition
module |
T321 |
| |
Signal conditioner /PID
controller |
T331 |
| |
Signal conditioner + PID controller with
trip alarms |
T332 |
| |
Logic expansion module for any Tracker
320 or 330 |
T340 |
| |
T300 data sheet (pdf)
|
| |
T300 reference guide (pdf)
|
|
| |
T300 installation (pdf)
|
|
| |
T300 configuration software
|
|
|
|
|
Universal Temperature
Transmitter |
Universal
Temperature Transmitter Accepts most commonly used temperature sensors, slide
wire transducers or millivolt signals, isolates and transmits them as a 4-20mA
signal to a host system. The unit can be programmed by the user from a
selection of preset ranges selected by DIL switches or by the software package
RCPW if required. Universal input Loop powered
User selectable input DIN rail mounting |
18.25 mm wide 99.5 mm high 90
mm deep |
| |
|
SEM215 |
|
| |
Temperature Transmitter data sheet (pdf)
|
|
|
|
|
Powered Isolating Converter |
Accepts and retransmits most
common process signals - switch selectable ranges. Provides loop excitation for
both input and output. Both current and voltage outputs are available
simultaneously from a single input. The isolator can either be DIN rail or
surface mounted. Universal AC mains and DC powered versions are available.
Powers both loops User selectable input and output
AC and DC powered versions DIN rail or surface mount
|
22.5 mm wide 82 mm high 99 mm
deep |
| |
|
SEM1100 |
| |
Powered Isolating Converter data sheet
(pdf)
|
|
| |
Powered Isolating Converter User guide (pdf)
|
|
|
|
|
AC Current
Transducers |
These units accept high current AC
inputs and provide a proportional analogue DC signal output. Uses include
monitoring high current in control and measurement applications, e.g. mains
supply current drawn by an electric motor.
Standard
inputs: 0-1Amp and 0-5Amp RMS
Outputs: Voltage
outputs from 0-1V up to 0-10V (1-5V and 2-10V raised zero) current
outputs 0-1mA up to 0-20mA (1-5mA, 2-10mA and 4-20mA raised zero)
|
103mm high 50.8 mm wide 87.9mm
deep
|
| |
|
HC-FPA |
|
| |
AC current transducer data
sheet (pdf)
|
|
|
|
|
AC Voltage
Transducers |
A transducer for measuring
single-phase AC voltages. The AC voltage input is converted into a proportional
DC analogue signal output. Output signal ranges are selectable by switches on
the front panel.
Inputs: 100V, 250V, 400V,
500V others available to order Outputs: 0-5mA, 0-10mA, 0-20mA,
4-20mA, 0-5V, 0-10V, 2-10V |
|
89mm high 36 mm wide 65 mm
deep
|
| |
|
TM3U |
|
| |
AC voltage transducer data
sheet (pdf)
|
|

|
|
|
Tracker 211 Low-cost
Indicators Universal input (4 digits) |
The Tracker 211 can
be directly connected to most popular process sensors and is fully scalable for
mV, mA, voltage and resistance inputs. Six linearised thermocouple ranges with
cold junction compensation (up-scale sensor burn-out detection) and two RTD
ranges are provided. Temperature can be displayed in oC or oF. Zero, Tare and
Max./Min. memory functions are available on versions fitted with front panel
buttons. Configuration is via front panel pushbuttons (when fitted) or via
hidden buttons behind facia or via Windows software. Supplied with universal
mains operation (90-250VAC) or optional 10-32VDC/AC |
96mm wide 48 mm high 100mm
deep |
| |
With one Alarm Relay |
T211-A |
|
| |
Two Alarm Relays |
T211-B |
|
| |
Three Alarm Relays |
T211-C |
|
| |
Analogue Output, 1 Alarm relay |
T211-D |
|
| |
Analogue Output, 2 Alarm relays |
T211-E |
|
| |
Analogue Output, 3 Alarm relays |
T211-F |
|
| |
Optional front panel buttons |
suffix B |
|
| |
Optional green display |
suffix G |
|
| |
Configuration to user requirements
|
|
|
| |
Windows compatible configuration
software & special cable |
Prog-211 |
|
| |
low-cost digital indicator data sheet
(pdf)
|
|
| |
digital indicator user guide (~600kB pdf)
|
|

|
|
|
Programmable Panel Meter Tracker Series
220 (4 or 5 digits) |
A range of four models which can
be used for simple measurement-only applications or more demanding situations
requiring digital communications, alarms, maths functions and complex signal
conditioning. Powerful menu-driven software enables fast flexible set-up from
the front panel or via the serial communications interface. No adjustments of
internal potentiometers, internal links or plug-in cards are necessary. Any one
of thermocouple, RTD, resistance, 20mA, mV and 10V inputs can be directly
connected. Red LED display with 0.56" high digits. All models have a 24V
transmitter supply. Front panel is water resistant to IP 65. Display digits
0.56" available in red or green. |
96mm wide 48 mm high 173 mm
deep |
| |
4-digit display with 10V transducer
supply |
T221 |
|
| |
4-digit display as T221 but with two
alarm relays |
T222 |
|
| |
5-digit display with serial interface,
analogue o/p etc. |
T223 |
|
| |
5-digit display as T223 but with two
alarm relays |
T224 |
|
| |
Optional green display |
suffix G |
|
| |
Configuration to user requirements
|
|
|
| |
Windows compatible configuration
software |
Prog-220 |
|
| |
Programmable Panel Meter data sheet
(pdf)
|
|
| |
Panel meter user guide (1.5MB pdf)
|
|
| |
download
panel meter configuration software (2.2Mb)
|
|
|
|