Signal Converter |
A range of units
which convert from one form of signal to another. e.g. current to current,
current to voltage, voltage to voltage, voltage to current, resistance to
current or voltage, PRT to current or voltage, milli-volt to current or
voltage. Input and output are isolated. |
|
| |
Voltage or mA Input |
160-1 /1 |
| |
Resistance Input |
160-1 /2 |
| |
data sheet (pdf)
|
|
|
|
|
|
Integrator |
Or Voltage/current to
Frequency Converter, this unit will convert a voltage or current input signal
into pulses with respect to time; the pulse rate being proportional to the
magnitude of the input signal. |
|
| |
Pulse, Open Collector or External Counter
Output |
160-1 /0 |
|
| |
With Internal 7 digit non-reset Counter |
160-1 /1 |
|
| |
With Internal 6 digit Resetable Counter |
160-1 /2 |
|
| |
Relay Output Version |
160-1 /3 |
|
| |
data sheet (pdf)
|
|
|
|
|
|
Square root Integrator |
Converts an analogue signal
(voltage or current) into pulses with respect to time. The pulse rate is
proportional to the square root of the magnitude of the analogue signal.
This instrument may be used for
continuous integration of rate signals where the variable measured
is the square of the unknown quantity. With the addition of an external
counter, continuous totalisation may be recorded. A typical application would
be to record total volume through a pipeline where the flowrate is measured
with a DP transmitter (differential pressure is proportional to the
flow-rate2). |
|
| |
|
160-5/4 |
|
| |
data sheet (pdf)
|
|
|
|
|
|
Controller |
This unit provides
the continuous controller element of a process control loop and offers switch
selectable Proportional or Proportional plus Integral modes. The remote
analogue set-point version can provide a slave unit for cascade applications. |
|
| |
Controller with Local Set-point Control |
160-30 |
|
| |
Controller with Remote
Set-point Potentiometer |
160-31 |
|
| |
Controller with Remote
Analogue Signal Set-point |
160-32 |
|
| |
data sheet (pdf)
|
|
|
|
|
|
Signal Selector |
This unit selects one out of 12
current or voltage input signals. The output from the unit is voltage only.
Current loops are maintained on circuits not selected. Inputs are selected with
a 12 position rotary switch. The Signal Selector may be used for selecting
one of many inputs for a read-out display or chart recorder etc. |
|
| |
|
160-81 |
|
| |
|
|
|
|
|
|
Pulse Generator |
The 160-52 provides a pulsed
output signal for testing, simulation and other applications requiring switched
set-point frequencies. Up to five set-points are provided as standard and are
selected by a rotary switch on the front of the instrument. The output signal
may be put on hold by a remote output inhibit signal. |
|
| |
|
160-52 |
|
| |
data sheet (pdf)
|
|
|
|
|
|
160 Series Rack System |
Rack System to DIN 41494 width 84
HP (module widths are 7HP and 12 HP). A comprehensive range of accessories is
available including dust covers, sub-rack handles and EMC Shielding
Kits. |
|
| |
Basic Sub-Rack System |
|
| |
Blank Panels ( 7HP Width) |
|
| |
Adapter Board (converts 160 series to 220
series length) |
|
| |
data sheet (pdf)
|
|
|
|
|
|
160 Series Panel Wall, Panel and
DIN Rail Mounting Enclosures |
A versatile range of robust
impact resistant enclosures. Wall mounting versions feature a separate plug in
rear section which enables mounting, fixing of cables and wiring with the front
section safely set aside. |
 |
| |
160 Series Panel Mounting
Enclosure |
ENC160-1 |
|
| |
160 Series Panel Mounting
Enclosure With Door |
ENC160-2 |
|
| |
160 Series Wall Mounting
Enclosure |
ENC160-3 |
|
| |
160 Series Wall Mounting
Enclosure With Door |
ENC160-4 |
|
| |
160 Series DIN Rail Mounting
Enclosure |
ENC160-5 |
|
| |
160 Series DIN Rail
Mounting Enclosure With Door |
ENC160-6 |
|
| |
Optional Lock for
Enclosures With Door |
suffix /L |
|
| |
data sheet (pdf)
|
|
|
|
|
| |
|
|
|